Small collection-electrode monolithic CMOS sensors profit from a high signal-to-noise ratio and a small power consumption, but have a limited active sensor volume due to the fabrication process based on thin high -resistivity epitaxial layers. In this paper, the active sensor depth is investigated in the monolithic small collection-electrode technology demonstrator CLICTD. Charged particle beams are used to study the charge -collection properties and the performance of devices with different thicknesses both for perpendicular and inclined particle incidence. In CMOS sensors with a high-resistivity Czochralski substrate, the depth of the sensitive volume is found to increase by a factor two in comparison with standard epitaxial material and leads to significant improvements in the hit-detection efficiency and the spatial and time resolution.



Citation Styles

Harvard Citation styleDort, K., Ballabriga, R., Braach, J., Buschmann, E., Campbell, M., Dannheim, D., et al. (2022) Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode demonstrator CLICTD, Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1041, Article 167413. https://doi.org/10.1016/j.nima.2022.167413

APA Citation styleDort, K., Ballabriga, R., Braach, J., Buschmann, E., Campbell, M., Dannheim, D., Huth, L., Kremastiotis, I., Kroeger, J., Linssen, L., Munker, M., Snoeys, W., Spannagel, S., Svihra, P., & Vanat, T. (2022). Comparison of different sensor thicknesses and substrate materials for the monolithic small collection-electrode demonstrator CLICTD. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1041, Article 167413. https://doi.org/10.1016/j.nima.2022.167413


Last updated on 2025-10-06 at 11:44